Free CSLB C-10 Electrical Contractor Exam Practice Test
Realistic 115-question practice exam with instant feedback and score reports.
Pre-built exam — starts in seconds.
About this practice exam
Free CSLB C-10 Electrical Contractor Exam practice test with 115 realistic multiple-choice questions, instant grading, and explanations. Administered by PSI. Typical passing score is about 72%. Study with drill mode, category score reports, and a personalized review plan.
Exam format
- 115 multiple-choice practice questions
- Based on the PSI exam format
- Typical passing score: 72%
- Drill mode with instant feedback and explanations after each answer
- Category score reports every 25 questions
What's on the exam
This practice test mirrors the weighted categories on the real C-10 Electrical exam:
| Category | Weight |
|---|---|
| Installation & Wiring | 26% |
| Planning & Estimating | 18% |
| Safety | 18% |
| Service, Maintenance & Troubleshooting | 17% |
| NEC & Electrical Theory | 13% |
| Motors & Controls | 8% |
Study tips
- Review the official exam content outline before your first practice run.
- Take the full practice exam once to establish a baseline score by category.
- Focus review on categories where you score below the passing threshold.
- Re-take missed questions in drill mode until you can explain each correct answer.
- Schedule the real exam only after consistent passing scores on practice tests.
Sample C-10 Electrical practice questions
Try a few representative questions below. Each includes the correct answer and a short explanation — the same style you'll see in the full practice test.
- Question 1Planning & Estimating
You are estimating the cost for a new commercial installation that requires a 480V, 3-phase, 100A feeder supplying a bank of transformers. The feeder conductors will be installed in rigid metal conduit (RMC) with a maximum ambient temperature of 40°C. Based on NEC Table 310.16, what is the minimum size copper conductor required for the ungrounded feeder conductors, assuming standard 75°C terminations and no derating factors other than ambient temperature?
- A.1 AWG
- B.1/0 AWG(Correct)
- C.2 AWG
- D.1/0 AWG
Explanation
According to NEC Table 310.16, for 100A at 75°C, a 1/0 AWG copper conductor has an allowable ampacity of 150A. This is the smallest conductor with an ampacity equal to or greater than the 100A feeder rating. Using 1 AWG (135A) would be undersized. 2 AWG (125A) is also undersized. The question specifies 75°C termination, aligning with the typical rating for transformer lugs, and the ambient temperature of 40°C does not require derating for this conductor size as its base ampacity is significantly higher than the 100A load. For example, when installing a 100A feeder to a step-down transformer for machinery, selecting 1/0 AWG ensures proper operation and code compliance.
- Question 2NEC & Electrical Theory
You are installing a 480V, 3-phase, 60Hz motor with a nameplate FLA of 80A and a service factor of 1.25. The motor will operate continuously and is protected by inverse-time circuit breakers. According to NEC Article 430, what is the minimum size copper conductor required for this branch circuit, considering THHN insulation and a maximum ambient temperature of 30°C?
- A.3 AWG
- B.1/0 AWG(Correct)
- C.4 AWG
- D.1 AWG
Explanation
According to NEC Table 310.16, THHN conductors at 75°C have an ampacity of 110A. For continuous loads, the conductors must be sized at 125% of the FLA (80A * 1.25 = 100A). For motors with a service factor of 1.25 or greater, the minimum conductor ampacity is 125% of the FLA, which is 100A. Looking at Table 310.16, 1/0 AWG copper THHN conductors are rated for 150A at 75°C, which satisfies the 100A minimum requirement. 1 AWG is rated for 130A, 3 AWG for 100A, and 4 AWG for 85A. Therefore, 1/0 AWG is the minimum size required. Incorrect options: 1 AWG is insufficient if the 100A requirement dictates a higher ampacity, 3 AWG is exactly 100A but the table often requires a step up due to rounding and specific conditions, and 4 AWG is too small. This is a common calculation for motor feeders on job sites.
- Question 3NEC & Electrical Theory
You are installing a 480V, 3-phase, 60Hz motor with a nameplate Full Load Amperes (FLA) of 70A and a Service Factor (SF) of 1.15. The motor will operate continuously and is protected by inverse-time circuit breakers. According to NEC Article 430, what is the minimum size copper conductor required for this motor branch circuit?
- A.1 AWG(Correct)
- B.3 AWG
- C.1/0 AWG
- D.2 AWG
Explanation
According to NEC Table 430.150, the minimum conductor ampacity for a 70A FLA motor is 87.5A (70A * 125%). For continuous duty, conductors must be sized at not less than 125% of the motor FLA. Using NEC Table 310.16, a 1 AWG copper conductor has an ampacity of 130A (assuming THHN, 75°C column, not more than three conductors in a raceway, ambient temperature 30°C), which is sufficient. Option A (2 AWG) is rated for 115A and is too small. Option C (1/0 AWG) is rated for 150A and is oversized. Option D (3 AWG) is rated for 100A and is too small. This ensures the conductors do not overheat under continuous load.
Want the full exam? Start the free practice test →
Frequently asked questions
How many questions are on this C-10 Electrical practice test?
This practice test includes 115 multiple-choice questions designed to mirror the format and difficulty of the real CSLB C-10 Electrical Contractor Exam.
Is this C-10 Electrical practice test free?
Yes. You can start practicing for free. Create an account to save progress, track weak categories, and retake the exam.
Do I get explanations after each question?
Yes. In drill mode you see why the correct answer is right, why distractors are wrong, and practical examples where relevant.
How should I use this practice test to prepare?
Take the full exam under timed conditions, review missed questions by category, then focus study on your weakest sections before scheduling the real exam.
Does this replace official PSI materials?
No. Use this as a supplement alongside official candidate information bulletins, textbooks, and hands-on experience required for your license or certification.
Related practice tests
Ready to test your knowledge?
Free 115-question practice exam — no sign-up required to try.